Code of Federal Regulations · Section
§ 18.98 — Enclosures, Joints, And Fastenings; Pressure Testing
30 C.F.R. § 18.98
View:
(a) Cast or welded enclosures shall be designed to withstand a minimum internal pressure of 150 pounds per square inch (gage). Castings shall be free from blowholes.
(b) Pneumatic field testing of explosion-proof enclosures shall be conducted by determining:
(1) Leak performance with a peak dynamic or static pressure of 150 pounds per square inch (gage); or
(2) A pressure rise and rate of decay consistent with unyielding components during a pressure-time history as derived from a series of oscillograms.
(c) Welded joints forming an enclosure shall have continuous gastight welds.
Authorizing Statute
-
Promulgation of regulations30 U.S.C. § 957