Code of Federal Regulations · Section
§ 50.19 — National Primary And Secondary Ambient Air Quality Standards For Ozone
40 C.F.R. § 50.19
(a) The level of the national 8-hour primary ambient air quality standard for ozone (O3) is 0.070 parts per million (ppm), daily maximum 8-hour average, measured by a reference method based on appendix D to this part and designated in accordance with part 53 of this chapter or an equivalent method designated in accordance with part 53 of this chapter.
(b) The 8-hour primary O3 ambient air quality standard is met at an ambient air quality monitoring site when the 3-year average of the annual fourth-highest daily maximum 8-hour average O3 concentration is less than or equal to 0.070 ppm, as determined in accordance with appendix U to this part.
(c) The level of the national secondary ambient air quality standard for O3 is 0.070 ppm, daily maximum 8-hour average, measured by a reference method based on appendix D to this part and designated in accordance with part 53 of this chapter or an equivalent method designated in accordance with part 53 of this chapter.
(d) The 8-hour secondary O3 ambient air quality standard is met at an ambient air quality monitoring site when the 3-year average of the annual fourth-highest daily maximum 8-hour average O3 concentration is less than or equal to 0.070 ppm, as determined in accordance with appendix U to this part.
Authorizing Statute
-
Congressional findings and declaration of purpose42 U.S.C. § 7401