Code of Federal Regulations · Section

§ 63.5875 — How Do I Determine The Capture Efficiency Of The Enclosure On My Wet-out Area And The Capture Efficiency Of My Oven(s) For Continuous Lamination/casting Operations?

40 C.F.R. § 63.5875

View:

(a) The capture efficiency of a wet-out area enclosure is assumed to be 100 percent if it meets the design and operation requirements for a permanent total enclosure (PTE) specified in EPA Method 204 of appendix M to 40 CFR part 51. If a PTE does not exist, then a temporary total enclosure must be constructed and verified using EPA Method 204, and capture efficiency testing must be determined using EPA Methods 204B through E of appendix M to 40 CFR part 51.

(b) The capture efficiency of an oven is to be considered 100 percent, provided the oven is operated under negative pressure.

Authorizing Statute