Code of Federal Regulations · Section
§ 1065.284 — Zirconium Dioxide (zro2) Air-fuel Ratio And O2 Analyzer
40 C.F.R. § 1065.284
View:
(a) Application. You may use a zirconia (ZrO2) analyzer to measure air-to-fuel ratio in raw exhaust for continuous sampling. You may use O2 measurements with intake air or fuel flow measurements to calculate exhaust flow rate according to § 1065.650.
(b) Component requirements. We recommend that you use a ZrO2 analyzer that meets the specifications in § 1065.205. Note that your ZrO2-based system must meet the linearity verification in § 1065.307.
Authorizing Statute
No authorizing statute found.