Code of Federal Regulations · Section
§ 64.61 — Rupture Disc
46 C.F.R. § 64.61
View:
If a rupture disc is the only pressure relief device on the tank, the rupture disc must—
(a) Rupture at a pressure of 125 percent of the maximum allowable working pressure; and
(b) Have a minimum normal venting capacity that is sufficient to prevent the tank pressure from exceeding 137.5 percent of the maximum allowable working pressure.
Authorizing Statute
-
Regulations46 U.S.C. § 3306