§ 119.530 — Bilge High Level Alarms
46 C.F.R. § 119.530
View:
(a) Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level in each of the following normally unmanned spaces:
(1) A space with a through-hull fitting below the deepest load waterline, such as a lazarette;
(2) A machinery space bilge, bilge well, shaft alley bilge, or other spaces subject to flooding from sea water piping within the space; and
(3) A space with a non-watertight closure , such as a space with a non-watertight hatch on the main deck.
(b) A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.