Code of Federal Regulations · Section
§ 153.515 — Special Requirements For Extremely Flammable Cargoes
46 C.F.R. § 153.515
View:
When Table 1 refers to this section:
(a) An enclosed space containing a cargo tank must have an inerting system that meets the requirements in § 153.500 applying to the inert gas system of a containment system;
(b) Cargo discharge pumps must be of a type that does not subject the shaft gland to the cargo under pressure or that is submerged; and
(c) The cargo tank's relief valve setting must be no less than 21 kPa gauge (approx. 3 psig).
Authorizing Statute
-
Administration and enforcement33 U.S.C. § 1903
-
General regulatory authority49 U.S.C. § 5103
-
Regulations46 U.S.C. § 3703