Code of Federal Regulations · Section

§ 153.1126 — Discharge Of Nls Residue From A Slop Tank To The Sea: Categories A, B, C, And D

46 C.F.R. § 153.1126

View:

NLS residue in a slop tank may not be discharged into the sea unless—

(a) The ship meets the conditions for discharging the NLS residue from a cargo tank in § 153.1128; and

(b) For Category B NLS residue transferred to the slop tank under § 153.1119(b), the NLS is discharged—

(1) Through an NLS residue discharge system with the flow recording equipment required in § 153.481(b)(2) operating; and

(2) At a rate maintained at or below Q in the following:

For tank contents that are miscible

For tank contents that are immiscible

Q = KU

1.4 L

1.6 × 10−5 m

3/hr

where:

Q = maximum permissible slops discharge rate in cubic meters per hour.

V = volume of slops in the tank in cubic meters.

K = 4.3, except K = 6.45 if Q is distributed between two NLS residue discharge outlets on opposite sides of the ship (see §§ 153.470(c) and 153.481(b)).

U = ship's speed in knots.

L = ship's length in meters.

N = number of tanks containing Category B NLS residue pumped into the slop tank.

Authorizing Statute