§ 154.1330 — Liquid Level Alarm System: Independent Tank Type C
46 C.F.R. § 154.1330
View:
Independent tanks type C need not have the high liquid level alarm system under § 154.1325 if:
(a) The tank volume is less than 200 m
3 (7,060 ft.
3); or
(b) The tank can withstand the maximum possible pressure during loading, that pressure is below the relief valve setting, and overflow of the tank cannot occur.