§ 154.506 — Mechanical Expansion Joint: Limits In A Piping System

46 C.F.R. § 154.506

View:

Mechanical expansion joints in a piping system outside of a cargo tank:

(a) May be installed only if offsets, loops or bends cannot be installed due to limited space or piping arrangement;

(b) Must be a bellows type; and

(c) Must not have insulation or a cover unless necessary to prevent damage.