Code of Federal Regulations · Section
§ 154.701 — Cargo Pressure And Temperature Control: General
46 C.F.R. § 154.701
View:
Except as allowed under § 154.703, cargo tanks must:
(a) Have their safety relief valves set at a pressure equal to or greater than the vapor pressure of the cargo at 45 °C (113 °F) but not greater than the MARVS under § 154.405; or
(b) Be refrigerated by a system meeting § 154.702, and each refrigerated incompatible cargo refrigerated by a separate system.
Authorizing Statute
-
Regulations46 U.S.C. § 3703