Code of Federal Regulations · Section
§ 162.050-19 — -19 Oil Content Meter And Bilge Alarm Test Rig
46 C.F.R. § 162.050-19
View:
(a) This section contains requirements for test rigs used in approval testing of oil content meters and meter. A typical test rig is described in Figure 162.050-19. The mixture pipe shown in Figure 162.050-19 is the portion of test rig piping between the oil injection point and the meter or bilge alarm piping.
(b) Each sample point on a test rig must be of the type described in Figure 162.050-17(e) and must be in a vertical portion of the test rig piping.
(c) Each test rig must have a centrifugal pump that is designed to operate at 1,000 revolutions per minute or more.
(d) The mixture pipe on a test rig must have a uniform inside diameter.
Authorizing Statute
-
Oil and hazardous substance liability33 U.S.C. § 1321
-
Regulations46 U.S.C. § 3306