Code of Federal Regulations · Subpart
Subpart F — Electrical Equipment—general
30 C.F.R. pt. 75, subpt. F
- § 75.500 Permissible Electric Equipment
- § 75.501 Permissible Electric Face Equipment; Coal Seams Above Water Table
- § 75.502 Permits For Noncompliance
- § 75.503 Permissible Electric Face Equipment; Maintenance
- § 75.504 Permissibility Of New, Replacement, Used, Reconditioned, Additional, And Rebuilt Electric Face Equipment
- § 75.505 Mines Classed Gassy; Use And Maintenance Of Permissible Electric Face Equipment
- § 75.506 Electric Face Equipment; Requirements For Permissibility
- § 75.507 Power Connection Points
- § 75.508 Map Of Electrical System
- § 75.509 Electric Power Circuit And Electric Equipment; Deenergization
- § 75.510 Energized Trolley Wires; Repair
- § 75.511 Low-, Medium-, Or High-voltage Distribution Circuits And Equipment; Repair
- § 75.512 Electric Equipment; Examination, Testing And Maintenance
- § 75.513 Electric Conductor; Capacity And Insulation
- § 75.514 Electrical Connections Or Splices; Suitability
- § 75.515 Cable Fittings; Suitability
- § 75.516 Power Wires; Support
- § 75.517 Power Wires And Cables; Insulation And Protection
- § 75.518 Electric Equipment And Circuits; Overload And Short Circuit Protection
- § 75.519 Main Power Circuits; Disconnecting Switches
- § 75.520 Electric Equipment; Switches
- § 75.521 Lightning Arresters; Ungrounded And Exposed Power Conductors And Telephone Wires
- § 75.522 Lighting Devices
- § 75.523 Electric Face Equipment; Deenergization
- § 75.524 Electric Face Equipment; Electric Equipment Used In Return Air Outby The Last Open Crosscut; Maximum Level Of Alternating Or Direct Electric Current Between Frames Of Equipment
- § 75.500-1 -1 Other Low Horsepower Electric Face Equipment
- § 75.501-1 -1 Coal Seams Above The Water Table
- § 75.501-2 -2 Permissible Electric Face Equipment
- § 75.501-3 -3 New Openings; Mines Above Water Table And Never Classed Gassy
- § 75.503-1 -1 Statement Listing All Electric Face Equipment
- § 75.506-1 -1 Electric Face Equipment; Permissible Condition; Maintenance Requirements
- § 75.507-1 -1 Electric Equipment Other Than Power-connection Points; Outby The Last Open Crosscut; Return Air; Permissibility Requirements
- § 75.508-1 -1 Mine Tracks
- § 75.508-2 -2 Changes In Electric System Map; Recording
- § 75.510-1 -1 Repair Of Energized Trolley Wires; Training
- § 75.511-1 -1 Qualified Person
- § 75.512-1 -1 Qualified Person
- § 75.512-2 -2 Frequency Of Examinations
- § 75.513-1 -1 Electric Conductor; Size
- § 75.516-1 -1 Installed Insulators
- § 75.516-2 -2 Communication Wires And Cables; Installation; Insulation; Support
- § 75.517-1 -1 Power Wires And Cables; Insulation And Protection
- § 75.517-2 -2 Plans For Insulation Of Existing Bare Power Wires And Cables
- § 75.518-1 -1 Electric Equipment And Circuits; Overload And Short Circuit Protection; Minimum Requirements
- § 75.518-2 -2 Incandescent Lamps, Overload And Short Circuit Protection
- § 75.519-1 -1 Main Power Circuits; Disconnecting Switches; Locations
- § 75.522-1 -1 Incandescent And Fluorescent Lamps
- § 75.523-1 -1 Deenergization Of Self-propelled Electric Face Equipment Installation Requirements
- § 75.523-2 -2 Deenergization Of Self-propelled Electric Face Equipment; Performance Requirements
- § 75.523-3 -3 Automatic Emergency-parking Brakes