§ 84.162 — Man Test For Gases And Vapors; Type C Respirators, Continuous-flow Class And Type Ce Supplied-air Respirators; Test Requirements
42 C.F.R. § 84.162
(a) The completely assembled respirator will be worn in a chamber containing 0.1 ±0.025 percent isoamyl acetate vapor, the intake of the hose will be connected to a suitable source of respirable air, and not more than 25 percent of the hose length will be located in isoamyl acetate-free air.
(b) The minimum flow of air required to maintain a positive pressure in the respiratory-inlet covering throughout the entire breathing cycle will be supplied to the wearer, provided however, that airflow shall not be less than 115 liters per minute for tight-fitting and not less than 170 liters per minute for loose-fitting respiratory inlet-coverings.
(c) The test will be repeated with the maximum rate of flow attainable within specified operating pressures.