§ 84.163 — Man Test For Gases And Vapors; Type C Supplied-air Respirators, Demand And Pressure-demand Classes; Test Requirements

42 C.F.R. § 84.163

View:

(a) The completely assembled respirator will be worn in a chamber containing 0.1 ±0.025 percent isoamyl acetate vapor, the intake of the hose will be connected to a suitable source of respirable air, and not more than 25 percent of the hose length will be located in isoamyl acetate-free air.

(b) The test will be conducted at the minimum pressure with the maximum hose length and will be repeated at the maximum pressure with the minimum hose length.